NFPA Pocket Guide to Fire Alarm System Installation

الغلاف الأمامي
Jones & Bartlett Learning, 2006 - 610 من الصفحات
This brand-new edition provides all the information you need to design, install, or maintain fire alarm systems. NFPA's Pocket Guide to Fire Alarm System Installation, Second Edition is updated to reflect the provisions of the 2007 edition of the National Fire Alarm Code (NFPA 72) and the 2005 edition of the National Electrical Code (NFPA 70). It has been reorganized to follow the order of topics presented within the NFAC, and includes updated requirements for power supplies, survivability, and spacing of detectors and notification appliances.
 

المحتوى

SECTION II
1
Radiation
2
FUNDAMENTALS
6
ELECTRICAL RELATIONSHIPS
10
Exhibit 11
11
Exhibit 11
16
CONVERSION FACTORS
23
Electrical Relationships Heat Release Rate Tables Conversion
43
SECTION IX
260
WIRING
264
12 Separations of Class 2 and Power Circuits
277
18b Wiring Method for Pigtail Connections
284
22b Wiring Method for Multiriser IDC Circuit
290
25 Dimensions of Insulated Conductors
305
CABLES
316
31 Cable Uses and Permitted Substitutions
322

Mean Annual Days with
46
EMERGENCY SYSTEMS DEFINITIONS
92
SECTION IV
94
GENERAL
95
11 Typical Performance Characteristics
109
16 PLFA Alternating Current Power Source
116
SECTION V
121
9 Heat Detector Spacing for Rectangular
129
11 Heat Detector Spacing for Irregular
131
SMOKE DETECTOR MOUNTING AND SPACING
144
36b Smoke Detector Spacing Based on High
157
Fire AlarmRelated Definitions Emergency Systems Definitions
158
39 Detector Location Requirements
160
49 Typical Duct Velocities ftmin
174
SECTION VI
176
CIRCUITS
177
8 Loading Capacities of Initiating Device
183
13 Smoke Detector Requirements for HVAC
187
28 Class A NAC and a 2hr Rated Cable
197
SECTION VII
199
Notification Appliance Mounting Audible Notification Appliances
200
4 Typical Audible CharacteristicsPublic
203
10b Visible Notification Appliance
209
11 Room Spacing for Wall Mounted Visible
210
14 Spacing of Wall Mounted Visible
216
Visible Notification Appliances Visible Equivalency
218
18 Corridor and Elevator Area Spacing
222
SECTION VIII
227
PERFORMANCE CRITERIA
228
2 Central Station Service Elements
234
9 Communications Media for
254
33 Communications Cable Types
324
47 Dimensions and Percent Area of Rigid
337
48 Dimensions and Percent Area of Type
339
51 Maximum Number of Same Size
348
53 Maximum Number of Same Size Compact
356
55 Maximum Number of Same Size Compact
365
57 Maximum Number of Same Size Compact
374
59 Maximum Number of Same Size
382
61 Maximum Number of Same Size
390
63 Maximum Number of Same Size Compact
398
65 Maximum Number of Same Size Compact
407
67 Maximum Number of Same Size Compact
416
69 Maximum Number of Same Size Compact
425
71 Maximum Number of Same Size Compact
434
73 Maximum Number of Same Size Compact
440
78 Volume Allowance Required
446
SECTION X
449
METHODS AND FREQUENCIES
453
3 Testing Frequencies
478
4 Visual Inspection Frequencies
486
6 Voltage for Lead Acid Batteries
490
SECTION XI
491
3 Inspection and Testing Form
508
4 Example Battery Calculation
522
14 Site Work Symbols
535
18 Fire Alarm Notification Appliance
546
23 Fire Service or Emergency Telephone
552
List of Resources
557
INDEX
565
حقوق النشر

طبعات أخرى - عرض جميع المقتطفات

عبارات ومصطلحات مألوفة

معلومات المراجع